Once the maintenance or the repair operations are
completed, before re-commissioning the stove,
install again all the protections and restart all the
safety devices.
6.1.1 FLUE SYSTEM MAINTENANCE
To be performed at least once a year, or every 40 tons
of burned pellets.
If there are horizontal sections, it is necessary to
check and remove any ash and soot deposits before
they block the passage of the flue gases.
In the event of failure or inadequate cleaning, the
stove may have functional problems such as:
-
bad combustion
-
glass blackening
-
blockage of the burn pot with accumulation of ash
and pellets
-
risk of flue catching fire.

6.1.2 STOVE MAINTENANCE

It must be carried out at least once a year, or each
time the stove indicates that maintenance is required.
During the maintenance operation, the technician
must:
-
clean the flue gas passage area thoroughly and
completely;
-
check the condition and tightness of all the seals;
-
check the condition of all internal components and
make sure they are clean;
-
make sure the flue gas outlet connection is sealed
and clean;
-
remove any deposits of pellet residues in the tank;
-
make sure that the stove is working properly;
-
reset any warnings or alarms
-
For easy access to the fan (A), just remove the lid
(D), the cap (B) and relevant gasket, then turn the
two screws (C) (Fig. 6.1.2).

6.1.3 GASKET REPLACEMENT

If the gaskets of the fire door, tank or flue gas chamber
become worn, they must be replaced by an authorised
technician in order to guarantee the proper operation
of the stove.
ATTENTION: Use only original spare parts.
6.1.4 CLEANING THE STOVE'S FLUE GAS
EVACUATION DUCT (ONLY FOR VERSIONS
WITH UPPER OUTLET)
It is recommended to carry out the cleaning operations
with the stove off and cold. Every 500 kg of pellets
burnt, the flue gas evacuation compartment needs to
be cleaned of any residue.
Remove the lid (D) (Fig. 6.1.2). Remove the screws
securing the left side (Fig. 6.1.3a). Dismantle the flue
gas pipe (A), the T-fitting (B) and cap (C) (Fig. 6.1.3b).
Use a flexible brush to clean the flue gas pipe. Finish
cleaning by vacuuming any ash residue in the cap and
fan using a suitable ash vacuum. Upon completion,
refit the components of the flue gas evacuation duct
and the side panel.