• Clean the equipment regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
parts in the equipment. Ensure that no water can
get into the interior of the equipment.
• You must disconnect the hose and any spraying
tools from the compressor before cleaning. Do not
clean the compressor with water, solvents or the
like.
10.2 Maintenance work on the pressure vessel/
condensed water (fig. 1)
m Important!
To ensure a long service life of the pressure vessel
(5), drain off the condensed water by opening the
drain valve (7) each time after using.
Release the vessel pressure first (see 10.7.1).
Open the drain screw by turning counter-clockwise
(looking at the screw from the bottom of the compres-
sor) so that all the condensed water can run out of
the pressure vessel. Then close the drain screw again
(turn it clockwise).
Check the pressure vessel for signs of rust and dam-
age each time before using. Do not use the compres-
sor with a damaged or rusty pressure vessel. If you
discover any damage, then please contact the custom-
er service workshop.
10.3 Safety valve (fig. 2)
The safety valve (15) has been set for the highest per-
mitted pressure of the pressure vessel. It is not permit-
ted to adjust the safety valve or remove the connection
lock (15.2) between the exhaust nut (15.1) and its cap
(15.3).
Actuate the safety valve every 30 operating hours but
at least 3 times a year, to ensure that it works when
required. Turn the perforated exhaust nut (15.1) coun-
terclockwise to open it and use your hands to pull the
valve rod outwards over the perforated exhaust nut
(15.1) to open the safety valve outlet. Now, the valve
audibly releases air. Then, tighten the exhaust nut
clockwise again.
10.4 Checking the oil level at regular intervals (fig. 9)
Place the compressor on a level and straight surface.
The oil level must be between the MAX and MIN marks
on the oil level window (17).
Oil change: we recommend SAE 15W 40 or equivalent.
The original oil filling must be changed after 10 hours
in operation; thereafter the oil must be drained and re-
placed with new oil after every 50 hours in operation.
10.5 Changing the oil (fig. 9)
Switch off the engine and pull the mains plug out of
the socket. After releasing any air pressure you can
unscrew the oil drain plug (18) from the compressor
pump. To prevent the oil from running out in an un-
controlled manner, hold a small metal chute under the
opening and collect the oil in a vessel.
If the oil does not drain out completely, we recommend
tilting the compressor slightly. When the oil has drained
out, re-fit the oil drain plug (18).
Dispose of the old oil at a drop-off point for old oil.
To fill in the correct quantity of oil, make sure that the
compressor stands on an even surface. Fill new oil
through the oil filler opening (fig. 8 pos. 12.1) until it
comes up to the maximum level. This is marked with
a red dot on the oil level window (17) (fig. 9 pos. 17.1).
Do not exceed the maximum filling quantity. Overfilling
the equipment may result in damage. Reinsert the oil
sealing plug (fig. 8 pos. 12) into the oil filler opening
(fig. 8 pos. 12.1).
10.6 Cleaning the intake filter (fig. 11, 12)
The intake filter prevents dust and dirt being drawn in.
It is essential to clean this filter after at least every 300
hours in service. A clogged intake filter will decrease
the compressor's performance dramatically. Open the
thumb screw (G) to the remove the intake filter.
Then pull off the filter cover (J). Now you can remove
the air filter (L) and the filter housing (K). Carefully tap
out the air filter, Filter cover and filter housing. Then
blow out these parts with compressed air (approx.
3 bar) and reinstall in reverse order.
10.7 Storage
m Important!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Switch
off the compressor and make sure that it is se-
cured in such a way that it cannot be started up
again by any unauthorized person.
m Important!
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted!
www.scheppach.com
GB | 25

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

5906135901

Tabla de contenido