Check Operation and Adjustment
Note: When first turned on or when switching modes wait 30
seconds.
Locate the RANGE control and ON-TIME control on the motion
sensor:
• The RANGE control and ON-TIME control are located on the bottom
of the motion sensor. Using your fingernails or a small, flat-head
screwdriver, gently pry the cover until it opens.
1. Check Operation. Set the ON-TIME control to TEST mode. Walk in
front of motion sensor. The LED indicator light should flash when
motion is detected (see illustration for location of LED light).
2. Adjust Motion Sensor. Turn the RANGE control to the minimum
position (MIN) and ON-TIME control to the TEST position.
Walk through coverage area noting where you are when the
LED begins to flash. Loosen the clamp screw and move the
motion sensor to change the coverage area. Tighten clamp
screw when finished. Do not overtighten clamp screw.
3. Adjust RANGE Control. To increase sensitivity, turn the RANGE
control toward MAX. To decrease sensitivity, turn the RANGE
control toward MIN. Note: If the RANGE is set too high, false
triggering may result in some environments.
Note: When using test mode to check operation in the day time:
A. Set the DETECT control switch to DAY/NIGHT and
B. Set the ON-TIME control to TEST.
4. Set ON-TIME Control. Determine the amount of time you want
the connected device to stay on after motion is detected (1 or
5 minutes). Slide the ON-TIME control to the corresponding
setting.
D
B
ual
rite
(Model 6032 Only)
IMPORTANT: The D
B
ual
the security light receivers. If this sensor will be used with a
security light receiver, the D
the OFF position.
The D
B
control turns the light on at half power for the
®
ual
rite
selected amount of time after dusk (Off, 3 or 6 hours, until dawn).
When motion is sensed, the light turns on full power for the selected
ON-TIME (1 or 5 minutes) then returns to accent mode.
1. Select amount of time desired for accent lighting (D
control).
• Off
• 3 Hours
• 6 Hours
• Dusk to Dawn
IMPORTANT: Avoid aiming motion sensor at:
• Objects that change temperature rapidly, such as heating vents,
fans, and air conditioners. These air sources could cause false
triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light colored objects reflecting light may trigger the
shut-off feature. Do not point other lights at motion sensor.
Dimmer Control
®
control does not function with
®
rite
B
switch should be left in
®
ual
rite
ON-TIME
Control
180° Motion Sensor Controls - Model 6030
LED Indicator
240° Motion Sensor Controls - Model 6032
LED Indicator
B
®
ual
rite
240° Motion Sensor Controls - Model 6062
4
ON-TIME
RANGE
(MINUTES)
MAX
MIN
5
1
TEST
RANGE
MAX
MIN
DUSK TO
6 3
OFF
TEST 1 5
DAWN
HRS
(MINS)
DUALBRITE™
ON-TIME
RANGE
MAX
MIN
TEST 1 5
(MINS)
ON-TIME
Range
Control
LED
Indicator
Range
Control
ON-TIME
Control
Range
Control
ON-TIME