Rutland 914i Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Rutland 914i Windcharger
Installation & Operation
5. If the wind turbine fails to deliver any current or open circuit V reading
undertake the further tests below.
6. Mechanical inspection. It may be necessary to remove the windcharger from
its pole for the following tests.
Check the brushes and slipring for wear or damage. To inspect the brushes,
remove the nacelle by removing the three fixing screws and slide the nacelle
backwards towards the tail fin. The brushes and slipring can be inspected by
removing the four self-tapping screws holding the brush holder assembly in place.
Remove any black deposits from slipring with emery paper. Heavy deposits and
reduced power indicate a possible reverse connection to the battery (see Page 11).
Check hub for free rotation with generator disconnected from battery.
If the hub does not rotate freely, check for a possible short circuit in the wiring. If no
wiring fault is found refer to your dealer or manufacturer.
If the above checks have identified a need for spare parts or failed to identify the
problem you should contact Marlec who can advise you of your nearest
distributor in their world wide network. In the first instance we recommend that you
contact the company from whom the product was originally purchased.
If in doubt, refer to your dealer or manufacturer.
Doc No:SM-137 Iss. E 11.03.19
20
Marlec Eng Co Ltd

Publicidad

Tabla de contenido
loading

Productos relacionados para Rutland 914i

Tabla de contenido