Descargar Imprimir esta página

Console Unit; Part 1: General; Part 2: Installation Requirements; Part 3: Electrical Requirements - Haier Arctic Serie Manual De Instrucciones

Ocultar thumbs Ver también para Arctic Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

CONSOLE UNIT

Part 1: General

1.1 Description
A. The floor console indoor section completes the system when connected to the matching outdoor unit and field-
supplied piping and wiring.
1.2 Warranty
A. The floor console indoor unit shall be covered by a manufacturer's parts warranty. See Appendix for detail.
1.3 Sound Pressure Rating

Part 2: Installation Requirements

2.1 Condensate
A. The floor console indoor shall be shipped with an insulated polyethylene condensate tubing (5/8" ID) attached from
the factory.
B. The floor console indoor unit shall ship with a 6.5 ft (2m) corrugated drain tube that connects to the insulated
drain tube.
C. The floor console indoor unit shall be a gravity drain.
2.2 Clearances
A. The installer must follow the minimum clearances illustrated in the Installation Manual when installing the indoor unit.
2.3 Mounting
A. The floor console indoor unit may be installed on the floor or low on the wall.
B. The floor console indoor unit shall ship with a galvanized metal wall bracket.
C. The wall bracket shall have multiple anchor points to provide the installer with many options to firmly attach the wall
mounted indoor unit to the wall.
D. The field-supplied mounting hardware must be sufficient to adequately support the indoor unit.
Part 3: Part 3 Electrical Requirements
3.1 Electrical Disconnect
A. Connecting wire must be continuous (without break) unless local code requires a disconnect at the indoor unit.
B. If a disconnect is required by local code, it must be a 3-pole, single-throw type.
31-5000585 Rev. 0
Model
Blower Pressure Sound Rating dB(A) (turbo/high/medium/low/quiet)
USYF09UCDWA
USYF12UCDWA
USYF18UCDWA
Model
USYF09UCDWA
USYF12UCDWA
USYF18UCDWA
40/36/32/25/20
42/38/34/26/21
46/42/37/33/28
Fan Motor Rating (HP)
0.04