General Safety; Electrical Safety; Safety In Use And Contact With Water; Safety In Operation And Maintenance - Astralpool DANCER JET Manual De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
1

GENERAL SAFETY

1.1

ELECTRICAL SAFETY

Disconnect the unit from the power supply before doing any assembly or maintenance
-
jobs.
Do not touch the water or get into the water while the unit is connected to the power
-
supply.
Connect the unit to an earth connection. Make use of one of the unit's fastening points
-
(see chapter 2.1).
Connect the unit to a power supply with an earth connection, protected by the following
-
components:
An RCD safety switch with a maximum residual current of 30 mA.
A circuit breaker fuse for a 10-A current.
Use an H07RN-F type waterproof cable.
-
1.2

SAFETY IN USE AND CONTACT WITH WATER

The water in the fountain where the unit is to be fitted must meet the following conditions:
-
Characteristics of the
water
Temperature
pH
Free residual chlorine
Total alkalinity (TAC)
Calcium hardness (CH)
Salt level
Total dissolved solids
(TDS)
If the temperature is below 4 ºC, empty the unit to prevent it from breaking due to the
-
formation of ice inside it.
Do not tamper with the factory-fitted waterproof seals. Otherwise, the unit could lose its
-
warranty.
1.3
OPERATION AND MAINTENANCE SAFETY
Risk of serious injury due to entrapment or the discharge of high-pressure water.
-
Set a minimum distance of 3 m between the unit and the fountain's perimeter.
Installation, operation and maintenance manual; Dancer jet
Minimum value
4 °C
6.9
0.5 ppm
80 ppm
200 ppm
-
-
Maximum value
35 °C
7.8
2.0 ppm
120 ppm
1,000 ppm
2 g/l
2,000 ppm
[en]
Fountain units
17

Publicidad

Tabla de contenido
loading

Tabla de contenido