3 Technical data
Table 3.1 Technical data
Item
Weights
• Without hose
• With hose and nozzle
Duct connection
Recommended airflows
• For cars, 100 mm (4") hose
• For trucks, 125/150 mm (5"/6") hose
Ambient temperature
Exhaust temperature
Hose temperature resistance
• HoseNR-CP
• HoseNFC-3
Power supply
Power consumption
Protection class
Noise level
Material recycling
4 Mounting instruction
See pictures on
Figure
height is depending on the hose length and weight.
NB! The maximum allowed uncoiled free-hanging
hose weight including nozzle is 30 kg. Choose such
mounting height so that the hose in uncoiled posi-
tion can be connected to the vehicle's exhaust pipe
without being stretched.
1
Make sure that the surface, on which to mount the
reel, is level. Drill 4 holes, using the hole template
which comes in the package.
2
Fit the mounting brackets in such a way that it will
make the reel hanging horizontally. Ensure that
suitable fixing bolts are used considering the ceil-
ing or wall construction material. The bolts must
each stand a tractive force of a minimum 6500 N.
12
Exhaust Hose Reel
Dimension
31 kg (68 lbs)
40 – 50 kg (82 – 110 lbs)
Ø 160 mm (6.3 in)
400 – 600 m
800 – 1200 m
-10 °C to +50 °C (15 °F to 120 °F)
Maximum 300 °C
150 °C (300 °F) continuously
300 °C (570 °F) continuously
100 V, 115 V, 200 V, 230-240 V AC 1-phase, 50/60 Hz
Maximum 325 VA
IP 44
Measured according to ISO 11201. < 70 dB(A).
Reels without hose: 100 weight-%
2. The maximum mounting
3
/h (235 – 350 cfm)
3
/h (470 – 700 cfm)
3
Use approved lifting equipment to lift the reel.
Fasten the reel in the brackets.
4.1 Mounting the hose
See pictures on
Figure
3. When the reel has been
mounted and connected to the power supply, the
hose should be fitted (concerning reels delivered
without hose only). It should be noted that the reel
can not be rotated by hand.
1
Fasten the hose with a hose clip on the connecting
piece inside the drum.
2
Aim the hand control towards the indicator (re-
mote-controlled reel only). Press the UP-button
on the hand control. The indicator shows a fixed
red light. Release the button at the required hose
position.
3