Pegasolift W12 Guia Uso Y La Mantenimento página 187

Tabla de contenido

Publicidad

MAINTENANCE OF THE OLEODYNAMIC POWER UNIT
Periodically it is necessary to control the level of ole-dynamic power unit which directs
the lifting operations of the lifting group, in order execute the following instructions:
1) lower the lifting group at the minimum possible height
2) disconnect the start key (reference page 14 "Instruments" no. 1)
3) open the electronic components cover
4) control the level of the oil in the tank of transparent plastic (part 2); if necessary
unscrew the tank cap (part 3) and execute the filling up with oil for oleo-dynamic
circuits with a viscosity ISO VG46 with the help of a long funnel.
5) screw again with care the tank cap paying attention to not soil the oil with impurity.
6) close the electronic components cover.
EMERGENCY DESCENT OF THE FORK GROUP
In case of an electric failure with the load lifted, operate as follows to force the descent of
the forks:
1) Hold down the emergency valve (part 1) until the lifting group begins to descent.
2) Wait until the load arrives at the minimum possible height
3) Stop to hold down the emergency valve (part 1).
W10 INOX
1
3
2
ATTENTION: use only special oil for food type
SHELL CASSIDA FLUIDS HF ISO VG 46
(see complete specification at page 23)