8.

BATTERy CHARGING - AC CONNECTIONS

8.1
This battery charger, with auto line voltage select function, is for use on
nominal 120 volt and 240 volt circuits.
DANGER – Never alter AC cord or plug provided – if it does not fit the
outlet, have proper outlet installed by a qualified electrician. Improper
connection can result in a risk of an electric shock or fire.
8.2
Recommended minimum AWG size for extension cords for battery
chargers: An extension cord up to 25 feet must be 12 AWG; up to 50 feet
must be 10 AWG and must have the proper 20 amp rated plug and recep-
tacle as shown below.
8.3
Grounding Methods
This charger must be properly grounded. Make sure the AC outlet you are
plugging it into is properly grounded per local codes and regulations. If it
is not, have one installed by a qualified service person. Do not remove or
bypass the grounding pin on the plug or receptacle.