240 VAC Source
N
L1
Breaker Box
240 V
*Line Neutral
(White Curly Wire)
*Equipment
Ground
Neutral
Bus
*Connections at the
Circuit Breaker
Bond in accordance with national and local codes.
Open bonding lugs are located at the top of the junction box.
5. Make Electrical Connections – Latin America
NOTE: The electrical rating of the product is printed on a label on the lumbar end of the bath. The bath
with heated surface is designed to operate between 110 V and 240 V at either 50 Hz or 60 Hz.
WARNING: Risk of electric shock. Disconnect the power before performing the following
procedures.
WARNING: Risk of electric shock. Connect the bath to a properly grounded Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD) for protection against line-to-ground
shock hazard.
IMPORTANT! The white wire should be connected to the load neutral terminal on the GFCI or RCD
breaker. The green wire is the equipment ground and must be connected to the neutral bus in the main
circuit breaker box.
IMPORTANT! Some equipment and installations vary. Reference "Alternate Wiring Connection" as shown
for details.
Follow local electrical codes. Bond in accordance with local codes.
Remove the 120 V plug from the electrical cord on the junction box mounted to the control board.
Connect service to the junction box with a 240 V plug (not included) or hardwire connection.
For Wireless Music Kit: The kit requires installation of an electrical outlet within close proximity to
the amplifier location. Refer to the music kit installation instructions.
1237788-2-G
Typical Single-Pole
Circuit Breaker
with GFCI
Junction
Box
240 V
Load
Neutral
Field Wiring
(From Breaker Box
to Junction Box)
Provide suitable
strain relief.
8
Typical 240 V Wiring Connection
Black
(L1)
Alternate Wiring Connection
Brown
(L1)
Green
(Ground)
From Control
White
(Neutral)
Wire
Connector
Green with
Yellow Stripe
(Ground)
From Control
Blue
(Neutral)
Wire
Connector
Kohler Co.