Changing the Units of Measure:
With the myMET on, change the units of measure by
pressing the power key more than 5 seconds until "SEt"
appears on the LCD and then release the power key. "unt"
then appears on LCD. Under "unt" status, press the power
key to scroll to the desired unit. Wait for 5 seconds and the
meter will return to normal mode using the selected unit of
measure.
Modes
Wind Speed
Temperature
Others
Backlight
A red backlight provides illumination at night, while
preserving night vision. To turn the backlight off, press the
power key for more than 5 seconds until "SEt" appears on
LCD and then release the power key. "unt" then appears on
LCD. Press the power key longer to change the mode to
"bLE", Under "bLE" status, press power key to scroll on or
off. Wait for 5 seconds the meter will return to normal
mode with selected status of backlight.
Units of Measure:
myMET measures wind speed in 2
different units of measure: Miles Per
Hour & Meters Per Second. To switch
between units of measure, please
see the "Changing the Units of
Measure" section for instructions.
Wind speed:
Wind speed is only shown in the
selected unit of measure to the first
decimal place.
Ambient Temperature:
Displays the temperature in
Fahrenheit or Celsius. If Metric
Units of Measure are selected for
wind, then Celsius will be displayed
for temperature.
Wind-Chill:
Temperature is displayed as Wind
Chill when WCl is displayed on the
LCD. Wind Chill is the effective air
temperature on human skin, when
wind speed is considered.
Battery indicator:
The battery icon in the lower left
corner of the LCD indicates the
battery level.
Wireless signal:
The wireless icon in the upper left
corner of the LCD indicates that the
BT4.0 module is functioning.