6.1
Expansion card connection
7
Installation
7.1
Receipt of the product
7.2
Hydraulic connection
Installation and operating instructions Wilo-Isar BOOST5
Installation
WARNING
Risk of electric shock.
Hazards from electric current must be prevented.
CAUTION
Risk of material damage
Any device attached to the expansion card must be at separated extra-low voltage
(SELV).
Do not pull the electric cables attached to the main on/off switch when removing
the cover.
ƒ
Unscrew and remove the fastening screws on the cover.
ƒ
Partly remove the cover to access the expansion card terminal block.
Terminal block key
9-10
7-8
0 V
5-6
3-4 OUTPUT
1-2
INPUT
CAUTION
Risk of material damage
Position the product horizontally and level.
Install the product in a dry, well-ventilated location protected from frost. The
product is not designed for use outdoors.
Choose a location to suit the device dimensions (Fig. 3) where the connections will be
accessible.
Unpack the pump and recycle or dispose of the packaging in an environmentally re-
sponsible manner.
DANGER
Risk of physical injuries
The applicable regulations for the prevention of accidents must be complied with.
1-2
Output
3-4
5-6
7-8
9-10
Input
LEVEL SIGNAL - bridge in
absence of signal
ALARM SIGNAL – max
0.3 A @ 230 V AC / 1 A @
30 V DC
Not connected - Do not
use
0 V
Not connected
Not connected - Do not
use
en
27