Electrical Safety and Installation Requirements STANDARDS: This product meets the following standards U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Electrical Safety and Installation Requirements INSTALLATION ELECTRICAL—AUTO VOLTAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the label. ELECTRICAL—TYPE CLASS 1 EQUIPMENT THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet.
Página 5
AT-FS709 Installation Guide NETZKABEL Das Netzkabel sollte eine maximale Länge von 4,5 Metern, einen Nennwert von mindestens 6 A und 250 V haben, aus HAR-Material hergestellt und mit einer gepreßten, IEC 320 entsprechenden, Anschlußverbindung an einem Ende, und am anderen Ende mit einem im Land des Endverbrauchers geprüften Stecker ausgestattet sein.
Página 6
Electrical Safety and Installation Requirements ADVARSEL: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den omgivende luft i rummet for afkøling. BETJENINGSTEMPERATUR Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C. ALLE LANDE: Installation af produktet skal ske i overensstemmelse med lokal og national lovgivning for elektriske installationer.
AT-FS709 Installation Guide NORMES: ce produit est conforme aux normes de suivantes : MISE EN GARDE: dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. Emission d’interférences radioélectriques EN55022 Classe A MISE EN GARDE : conformément aux limites d’émission de la Classe A, ce produit doit être utilisé...
Página 8
Electrical Safety and Installation Requirements STANDARDIT: Tämä tuote on seuraavien standardien mukainen. VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. Radioaaltojen häirintä EN55022 Luokka A VAROITUS: Tämä tuote vaatii suojatut kaabelit täyttääkseen A Luokan säteilyrajoitukset. Ellei suojattuja kaapeleita käytetä, tämä...
Página 9
AT-FS709 Installation Guide STANDARD: Questo prodotto è conforme ai seguenti standard. AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A AVVERTENZA: questo prodotto richiede cavi schermati per adeguarsi ai limiti di emissione per gli apparecchi di Classe A.
Página 10
Electrical Safety and Installation Requirements SIKKERHETSNORMER: Dette produktet tilfredsstiller følgende sikkerhetsnormer. ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. RFI stråling EN55022 Klasse A ADVARSEL: Det må benyttes isolerte kabler med dette produktet for å tilfredsstille Klasse A strålingsgrenser.
Página 11
AT-FS709 Installation Guide PADRÕES: Este produto atende aos seguintes padrões. AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. Emissão de interferência de radiofrequência EN55022 Classe A AVISO: Este produto requer cabos protegidos a fim de obedecer aos limites de emissão da Classe...
Página 12
Electrical Safety and Installation Requirements ESTÁNDARES: Este producto cumple con los siguientes estándares. ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. Emisión RFI EN55022 Clase A ADVERTENCIA: este producto requiere de cables armados para cumplir con los límites de emisión de Clase A.
Página 13
AT-FS709 Installation Guide STANDARDER: Denna produkt uppfyller följande standarder. VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. Radiostörning EN55022 Klass A VARNING: Skärmkabel bör användas med denna produkt för att uppfylla kraven gällande radiostörningar enligt Klass A.
Table of Contents Electrical Safety and Installation Requirements ........iii Chapter 1 Product Description ..................1 Overview ......................1 Physical Description................... 2 Connectors ....................2 Front Panel LEDs..................3 MDI/MDI-X Button ..................3 Power Supply ....................4 Auto-Negotiation ....................4 Chapter 2 Installation ......................
Página 16
Table of Contents Appendix B Technical Support Fax Order ..............13 Incident Summary .................... 13 Appendix C AT-FS709 Switch Installation Guide Feedback ........15 Appendix D Where To Find Us ..................17...
Chapter 1 Product Description Overview This chapter describes the features of the AT-FS709 unmanaged Fast Ethernet switch, which includes: IEEE 802.3, IEEE 802.3u and IEEE 802.3x compliant Nine auto-negotiating 10/100 Mbps twisted pair RJ45 ports Store and forward switching at full-wire speed (14,880 packets per...
LINK 10BASE-T/100BASE-TX FAST ETHERNET SWITCH 10BASE-T/100BASE-TX NETWORK PORTS POWER Figure 1 AT-FS709 Front and Rear Panels Physical Description Connectors Table 1 lists and defines the type of connectors available and their function. Table 1 Connector Types on Switch Connector Type...
AT-FS709 Installation Guide Front Panel LEDs Figure 2 illustrates the switch front panel LEDs. Table 2 lists and describes these LEDs. 100Mbps 10BASE-T/100BASE-TX NETWORK PORTS STATUS POWER ACTIVITY LINK Figure 2 A Close Up of the Front Panel LEDs Table 2 LED Status...
120 VAC, or 200 to 240 VAC, 50/60 Hz input rating. The switch requires input of 100 to 240 VAC. Maximum power consumption is 20W. Allied Telesyn ships power cords with the units to the U.S., Continental Europe, and the U.K.
Before installing the switch, make sure you read “Electrical Safety and Installation Requirements,” page iii. Verifying Package Contents Make sure that the package includes the following items: One AT-FS709 switch One AC power cord (for the U.S., Continental Europe, and the U.K. only) Warranty card...
Installation Site Requirements Make sure you observe the following site requirements: Make sure you are placing the switch in a dust-free and moisture-free environment. Do not block ventilation openings on the unit. Make sure that the switch’s power is accessible and cables can be connected easily.
Figure 3 shows a 9-port switch connected to end stations and a server. The basic physical connection for this configuration requires connecting one of the switch’s ports to the adapter card of an end station. 10BASE-T/100BASE-TX NETWORK PORTS POWER Cat 5, UTP wiring Figure 3 AT-FS709 Connected to End Stations...
Installation Cascade Configuration Cascading means that two switches can be connected together using any of the switch ports, provided you maintain the same media type. Two switches can be cascaded to support multiple network port connections. Cable length to the nodes must follow the 100Base-TX cabling specifications.
10BASE-T/100BASE-TX NETWORK PORTS POWER HALF DUPLEX FULL DUPLEX POWER Finance AT-8124XL Switch 10BASE-T / 100BASE-TX FAST ETHERNET SWITCH 10BASE-T / 100BASE-TX PORT ACTIVITY RS-232 STATUS TERMINAL PORT LINK / RECEIVE 100M FAULT POWER RESET Figure 5 AT-FS709 Switches Conected to the Backbone...
Appendix A Switch Specifications Physical Characteristics Chassis dimensions: 12 in (L) x 7.2 in (W) x 1.5 in (H) 305 mm (L) x 182 mm (W) x 38 mm (H) Weight: 2.9 lbs (1.3 kg) Operating temperatures: 0° to 40° C Storage temperatures: -20°...
Switch Specifications Network Specifications Table 4 provides an overview of IEEE 802.3 and 802.3u specifications for 10Base-T and 100Base-TX network configurations using shielded twisted-pair wiring. Table 4 IEEE 802.3 and 802.3u Network Specifications 10Base-T 100Base-TX Media Shielded Twisted Pair Shielded Twisted Pair Category 3 or 5 Category 5 only Topology...
Conditions (List the steps that led up to the problem.) ________________________________ ______________________________________________________________________________ ______________________________________________________________________________ Detailed description (Use separate sheet, if necessary) ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page 17.
Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the guide.
FTP Server Address: gateway.centre.com [lowercase letters] Login: anonymous [lowercase letters] Password: your e-mail address [requested by the server at login] For Information Regarding Allied Telesyn International, Corp. Allied Telesyn International, Corp. Allied Telesyn International, Corp. 19015 North Creek Parkway 950 Kifer Road...