MAINTENANCE
Maintenance/repairs must be carried out by
competent and local regulations. Fan unit equip-
ment should be electrically isolated and locked
out before any work started.
Fan unit equipment should be regularly cleaned,
frequency depending upon service load and appli-
cation, but no less than every year. Cleaning should
include all areas where dust can accumulate in the
fan equipment.
Special attention should be made to any unusual
sounds, vibration or temperature. If any problems
are detected the fan unit equipment should be
stopped immediately and cause inspected. The im-
peller and blades should be regularly checked for
damage that could cause imbalance in the moving
parts
PUTTING OUT OF SERVICE
AND RECYCLING
EEC legislation and our consideration of
future generations mean that we should
always recycle materials where possible;
please do not forget to deposit all pack-
aging in the appropriate recycling bins. If
your device is also labeled with this symbol, please
take it to the nearest Waste Management Plant at
the end of its servicable life.
The fan unit is mainly made of steel, copper, fer-
rite, aluminium and plastic. These components
should be recycling in the following categories:
• Steel and iron
• Aluminium
• Non-ferrous metals
• Plastics
• Insulating materials
• Cables
• Electronic scrap
To clarify any questions regarding S&P products
contact your local distributor. For its location and
to obtain the EU Declaration of Conformity certifi ed
technical data sheet and copy of this instruction
manual, see our web site www.solerpalau.com
INFORMATION REQUIREMENTS FOR RVU
a Trade mark
b Identifi er
c SEC average climate (kWh/(m
SEC class
SEC cold climate (kWh/(m
SEC warm climate (kWh/(m
d Typology
e Type of drive
f Type of HRC
g Thermal effi ciency (%)
h Maximum fl ow rate (m
i Electrical power input at maximum fl ow rate (W)
j Sound power level (LWA)
k Reference fl ow rate (m
l Reference pressure difference (Pa)
3
m SPI (W/m
/h)
n Control factor
Control typology
o Maximum internal leakage for BVU (%)
Maximum external leakage for BVU and UVU (%)
p Mixing rate for BVU without duct connection (%)
q Position of visual fi lter warning
description of visual fi lter warning
r Instructions to install supply grilles
Instructions to install exhaust grilles
s Internet address
t Airfl ow sensitivity to pressure variation
u Indoor/outdoor air tighness (m
v Annual electricity consumption - Average climat
(kWh/a)
Annual electricity consumption - Warm climat
(kWh/a)
Annual electricity consumption - Cold climat
(kWh/a)
w Annual heating saved - Average climat (kWh/a)
Annual heating saved - Warm climat (kWh/a)
Annual heating saved - Cold climat (kWh/a)
2
.an))
2
.an))
2
.an))
3
/h)
3
/s)
3
/h)
11
EN