Appliance operating at the temperature setting shown on the display.
Appliance operating at temperature -3.5ºC below temp. indicated on the
display.
Appliance off but with anti-freeze function activated (appliance switches on
when temperature descends to 5ºC, maintaining temperature between 5 and
9ºC.
Appliance executing command sent by infrared remote control.
Appliance connected to home automation network and receiving commands
from controller.
The
mode and icon are only available from the first transmission from the
remote control (optional). Sufficient with transmission of time.
8.3 Temperature select
In standby position, the screen displays the room temperature (Ambient
temperature).
To select the desired temperature, press either the
or
keys, the screen will light up and each
successive pressing on
diminish the set temperature 1ºC respectively.
After 4 seconds without pressing any key, the
screen
will
return
temperature and in another 4 seconds the display
8.4 Maximum temperature settings.
Although the thermostat supports a temperature range between +5ºC and
+35ºC, this range can be reduced to limit the maximum temperature setting to
+15ºC, thus restricting the temperature range to between +5ºC and +15ºC.
Access to this function is protected by a non-intuitive programming procedure.
This function helps avoid energy waste. To reduce the maximum temperature,
proceed as follows:
1. Press
and hold the key for 2 seconds. The current maximum temperature
setting (35ºC by default) flashes on the display .
2. Press
and
Each press increases or reduces the temperature setting by 1ºC. Once 5
or
will increase or
to
displaying
to move the maximum temperature to the desired setting.