English
General safety requirements
`
`
Read these directions for use carefully before using.
`
`
Keep these directions for use where they will be
accessible for all users.
`
`
Failure to comply with the directions for use shall
render all warranty conditions null and void and
may lead to personal injury and material damage.
`
`
The instrument must only be used by qualified
skilled employees.
Safety instructions before using
`
`
Follow the manufacturer's instructions and safety
instructions of the medium you are filling.
`
`
Damage to the respiratory tract and other organs
due to off-gassing media. Fill only in ventilated
rooms or under a suitable exhaust hood.
`
`
When working with explosive substances, follow the
technical rules for combustible liquids (in accordan-
ce with TRBF – (German) Technical Rules on Com-
bustible Liquids) and wear appropriate protective
equipment (zone 0, see annex).
WARNING!
Possible sparking due to electrostatic discharge.
Danger of explosion if combustible liquids are used.
`
`
Connect the earthing terminal before use (see
accessories).
`
`
Wear the necessary protective clothing.
`
`
The instrument must only be used within the
confines of applicable material resistance and for its
designated purpose. Any other type of use will affect
the warranty/guarantee.
NOTE!
Before using, the instrument has to be cleaned to
the extent of your (validated) cleaning process.
`
`
Measures of manual cleaning have to be carried
out in the cleaning/desinfection area and under
consideration of occupational health and safety.
`
`
Pay attention to the material resistance.
Safety instructions during and after use
`
`
The instrument generates overpressure. Possible
bodily injury due to escaping liquids. Hold the shut-
off valve on the discharge hose closed.
`
`
The instrument generates overpressure. If there are
differences in pressure, loud popping noises can be
heard with some types of containers.
`
`
The instrument is not suitable for cleaning in a
dishwasher.
Layout and function
`
`
The instrument is made of conductive material
(1.4301).
`
`
The instrument is suitable for filling combustible
liquids in accordance with groups IIA and IIB (see
annex).
`
`
Always use the instrument with pressure-resistant
containers (up to 220 l, >1 bar) for filling into open
containers (<1 l).
`
`
When filling combustible liquids, always use an
antistatic set (see accessories).
The instrument is maintenance-free and suitable at
`
`
a temperature range from 0 to 60 °C.
Point out any damage in the packaging to the freight
forwarder/supplier immediately.
WARNING!
Possible electrostatic discharge. Danger of explosi-
on if combustible liquids are used.
`
`
Connect the earthing terminal before use (see
accessories).
`
`
Wear the necessary protective clothing.
WARNING!
Some liquid will continue to run while the dischar-
ge hose is being screwed on. Bodily injury due to
escaping liquid.
`
`
Close the shut-off valve on the discharge hose
before mounting.
Assembly
1. Guide the barrel screw connection and riser
pipe into the container and screw it together
finger-tight.
2. If necessary open the clamping lever and adjust
the riser pipe. Then close the clamping lever and
lock the riser pipe in place.
3. Screw the discharge hose onto the riser pipe
4. Attach the connecting hose to the foot bellows on
the instrument .