Precautionary Measures - SPIT 1630P Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Changing the motor protection filter
NOTE: If the motor protection filter is contaminated this indicates defective filter cassettes.
Replacing the folding filter cassettes.
Replace the motor protection filter or wash the motor protection filter under flowing water, dry
and re-insert.
mAINTENANCE
NOTE: Switch the vacuum cleaner off and pull out the mains plug before any maintenance work.
For maintenance by the user, the vacuum cleaner must be
dismantled,
cleaned and
maintained,
as far as possible without creating any danger to the maintenance personnel or other.

Precautionary measures

Suitable precautionary measures include
Cleaning before dismantling,
Provide local filtered positive ventilation where the vacuum cleaner is to be dismantled,
Clean the maintenance area and
suitable personal protection equipment.
Precautionary measures with vacuum cleaners class H and M
The outside of the vacuum cleaner should be cleaned and wiped down or should be treated with
a sealing agent before being removed from the dangerous area. All parts of the vacuum cleaner
must be considered to be contaminated when they are removed from the danger area and
suitable handling must be used to prevent dust distribution.
Contaminated items
When carrying out maintenance or repair work, all contaminated items which have not been
adequately cleaned must be disposed of. Such items must be disposed of in impermeable bags
in accordance with the applicable regulations concerning the disposal of such waste.
Technical testing
A technical examination must be carried out at least once a year by a trained person: check
the filter for damage, ensure that the vacuum cleaner is air-tight and check that the monitoring
equipment functions correctly.
Testing the effectiveness of the vacuum cleaner
NOTE: In addition, the effectiveness of the vacuum cleaner class "H" must be checked at least
once a year.
There must be an adequate air exchange rate L in the room if the exhaust air returns to the
room. Further information can be taken from your national regulations.
If the suction of the vacuum cleaner reduces and the cleaning procedure of the folding filter
cassettes increases, the suction performance is not adequate (provided that the container is
empty and the paper filter bag has been replaced) then it is necessary to replace the folding
filter cassettes.