MENU STRUCTURE
PROGRAMMING THE PARAMETERS
DISPLAYING THE PROGRAMMED PARAMETERS
Rev 1.0
During normal operation of the pump it is possible to display the programmed
parameters by pressing the SET button.
The dosing stops and the pump displays subsequently:
-nA and the programmed number of dosings
-tA and the programmed total minutes of daily dosing
-FL and the programmed percentuage of the flow rate.
Remember that FS means Full Speed = 100% = maximum flow rate
Cod. 00.008.565
Push OK/SBY and then the
SET button to enter the
programming menu.
Navigate within the menu by
pressing SET and enter the
sub-menu to modify the
parameters by pressing
OK / SBY.
Once you enter the menu, change the
parameters
nA,
tA,
OK/SBY button and then select the
desidered value by SET button and
confirm it by pressing OK/SBY.
Exit the programming confirming the
value of the percentuage flow rate (FL)
by pressing OK/SBY.
The programmable Values are:
nA = 1-24; number of daily dosings (1
dosing every hour)
tA = 1-99 minutes; total daily dosing
time
FL = 10% - FS (Full Speed = 100%),
percentuage of the maximum flow of
the pump.
FL
pressing
7