8 Specifications
Weight of instrument c/w Grinder-Compressor unit: 1kg
Dimensions of instrument c/w Grinder-Compressor unit:
195 mm length x 185 mm height x 100 mm width
Power: x1 6F22R 9V battery
LCD resolution: 0.1
Operating temperature range: 0 °C to 40 °C
%H
O measurement range: See Table 5 below.
2
Wheat: 11.3 to 29.3
Oats: 10.9 to 29.3
OSR: 7.0 to 26.0
Barley: 10.9 to 29.3
Note:
Not all calibrations are for Ground samples.
The information contained in this manual is given in good faith. As the method of use of the
instrument (and its accessories) and the interpretation of the readings are beyond the control of
the manufacturers, they cannot accept responsibility for any loss, consequential or otherwise,
resulting from its use.
Protimeter Grainmaster
Page 10
Table 5: % H
O Measurement Range
2
Canola: 7.0 to 26.0
Linseed: 7.0 to 16.5
Sunflower: 6.2 to 23.0
Corn: 10.4 to 26.2
®
is a registered trademark of Amphenol Thermometrics, Inc.
Coffee: 9.8 to 23.9
Soya: 7.4 to 22.2
Beans: 12.4 to 25.0
Peas: 12.0 to 30.9
Rice: 13.2 to 26.5
Sorghum: 10.2 to 26.9
Paddy: 10.4 to 26.2
0-100 relative
Protimeter Grainmaster