SYMPTOM
Engine will not start.
No discharge at nozzle when
trigger mechanism is squeezed.
Low or fluctuating pressure.
Oil leaking from unit.
Detergent will not siphon into
Low Pressure Detergent mode.
Water flows back into detergent
container.
Water flows from the nozzle when the
trigger gun is locked in the "OFF"
position.
18
TROUBLESHOOTING
PROBABLE CAUSE
Various engine problems.
Unit components are frozen.
Inadequate water supply.
Kink in water inlet hose.
Kink in high pressure discharge hose.
Water inlet filter obstructed.
Pump sucking air. (Prime eliminated)
Not in high pressure mode.
Obstructed or worn spray nozzle.
Damaged or obstructed valve assy.
on pump.
Pump packings worn.
Unloader valve not operating correctly.
DO NOT USE!!!!!
Detergent strainer is not completely
submerged in detergent solution.
Detergent strainer obstructed.
Detergent hose cut, obstructed or
kinked.
Not in low pressure mode.
Nozzle assembly is plugged.
Too many high pressure hose
extensions attached to the water outlet.
Ball & Spring in Venturi stuck.
Ball & Spring in Venturi reversed,
missing or corroded.
Gun is malfunctioning.
REMEDY
Refer to the Engine Manual
accompanying your unit.
Allow to thaw. If any part of the unit
becomes frozen; excessive pressure
may build up in the unit which could
cause the unit to burst resulting in
possible serious injury to the operator or
bystanders.
Ensure hose is 3/4" diameter and
incoming water supply is turned on.
Remove kink.
Replace hose.
Remove screen, clean or replace.
Tighten all water intake connections
Eliminate leaks in intake line.
Pull the nozzle cover toward gun.
Remove, clean or replace.
Remove, inspect, clean or replace.
Replace packings.
Repair or replace.
Contact Customer Service.
Check, submerge if necessary.
Inspect, clean or replace.
Inspect, clean or replace.
Push nozzle cover away from gun.
Clean or replace.
Use one extension maximum.
Remove, clean or replace.
Remove, clean or replace.
Repair or replace.