Safety Instructions And Warnings; General Safety Instructions; Use According To The Intended Purpose - Kübler CODIX 529 Instrucciones Para La Puesta En Servicio

Ocultar thumbs Ver también para CODIX 529:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Operating instructions
Digital display with analogue inputs
CODIX 529
Ordering code: 6.529.012.300

1.1 Safety instructions and warnings

Only use this display
– in a way according to its
intended purpose
!
– if its technical condition is
perfect
– adhering to the operating
instructions and the general
safety instructions.

1.2 General safety instructions

1. Before carrying out any installation or main-
tenance work, make sure that the power
supply of the digital display is switched off.
2. Only use this digital display in a way accord-
ing to its intended purpose: If its technical
condition is perfect. Adhering to the oper-
ating in structions and the general safety
instructions.
3. Adhere to country or user specific regu-
lations.
4. The digital display is not intended for use
in areas with risks of explosion and in the
branches excluded by the standard
EN 61010 Part 1.
5. The digital display should only operate if
it has been correctly mounted in a panel,
in accordance with the chapter "Technical
features".

1.3 Use according to the intended purpose

The digital display may be used only as a
panel-mounted device. Applications of this
product may be found in industrial processes
and controls, in manufacturing lines for the
metal, wood, plastics, paper, glass, textile and
other processing industries.
Over-voltages at the terminals of the digital
display must be kept within the limits in Cat-
egory II.
If the digital display is used to monitor
machines or processes in which, in case of a
failure of the device or an error made by the
operator, there might be risks of damaging the
machine or causing accidents to the operators,
it is your responsibility to take appropriate
safety measures.
1.4 Description
• 5-digit digital display with analogue inputs
• LED-Display with 8 mm high characters and
very high luminosity
• Display range -19999...99999 with leading
zero blanking
• Programming of functions and operating
parameters via the two setting keys. During
programming the display guides the user
with text prompts.
• Programmable features:
Range
Max. value display yes/no
Max. value reset yes/no
Min. value display yes/no
Min. value reset yes/no
Decimal point
Min. input signal
Displayed value at min. input signal
Max. input signal
Displayed value at max. input signal
2. Inputs
LATCH (Connect 4)
Static input freezing the displayed value.
If this input (pnp) is supplied with 4...30 V DC
the actual value is frozen until the input is
released or the signal level gets below 2 V
DC. The calculating of max. and min. value is
not af fec ted.
CURRENT INPUT (Terminal 5)
Analogue current input with reverse connection
pro tec tion and current limitation to max. 50 mA.
Connect the signal line with the analogue +
signal with this input.
Page 1

Publicidad

Tabla de contenido
loading

Tabla de contenido