4
MOUNTING
4
Mounting
5
Electrical installation
6
BluePilot blue: sensing range display
1
Press-turn element / Potentiometer / Teach-Button: adjusting the sensing range
2
LED indicator yellow: status of received light beam
3
LED indicator green: supply voltage active
4
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Figure 1: Alignment of the sensor relative to the object direction
Note the sensor's maximum permissible tightening torque of < 0,4 Nm.
Note the preferred direction of the object relative to the sensor, cf.
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Pin assignment
–
Cable: Wire color
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED flashes on the
sensor. IODD and function block are available to download from
the part number.
Explanations on connection diagram.
BN = brown
WH = white
BU = blue
BK = black
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = Test input
see figure 1, page
6.
www.sick.com
under
8025300.1BBX / 2021-05-12 | SICK
Subject to change without notice