4

Mounting

5

Electrical installation

8020348.19RH / 22.12.2020 | SICK
Subject to change without notice
WLA16x-xxxxxx30
1
6
3
2
BluePilot blue: alignment aid
1
LED indicator yellow: status of received light beam
2
LED indicator green: supply voltage active
3
Press-turn element: time function adjustment
4
Teach pushbutton: adjustment of light/dark switching
5
Teach-Button: adjusting the sensitivity
6
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment.
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram:
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 1: Connections
Wxx16x-
x4
1 = BN
4
2 = WH
3 = BU
4 = BK
5= GY
1
WLA16x-xxxxxx31
5
1
6
3
2
xH
3
4
0.14 mm
2
AWG26
2
1
MOUNTING
WLA16x-xxxxxx32
4
1
6
3
2
x5
xI
5
3
0.14 mm
2
AWG26
2
4
5

Publicidad