• When making scans in areas affected by undesired magnetic fields (e.g. in the vicinity of transformers, electric motors
or other appliances causing high magnetic interference) the data from the EM sensor is shown shaded in transparent
red. Please note that, in this case, the results of the scans may not be correct.
en
EM sensor data from a Quickscan shaded in red
• EM sensor sensitivity: Two-core cable (d = 5 mm) at a depth of 8 cm with I = 250 mA (45 - 65 Hz)
• Activate the EM sensor under Settings → Options, by setting the "EM sensor" to "On".
8
EM sensor data from an Imagescan shaded in red