Cleaning the Collector Cell

Note: The collector cell may require more frequent cleaning if "arcing" occurs. Arcing is a sharp snapping sound that
occurs when large particles of dust are collected in the collector cell. If prolonged or continuous arcing occurs the
collector cell should be cleaned.
5
7
IMPORTANT: Do not try to clean the collector cell by inserting a cloth, brush, or other object between the cell plates.
Unplug the air purifier.
1
Remove the top cover by sliding forward and lifting off.
2
Pull the collector cell straight up and out of the cabinet by using the two small handles on each side of the
3
collector cell.
Place in sink, bathtub or other location where cleaner and contaminants will rinse away without damaging surfaces.
4
Spray Oreck Assail-a-Cell
5
to soak for a few minutes and rinse with clean water. Do not let the cleaner dry on the collector cell.
An alternative method to clean the collector cell is to soak it in warm water for two to three hours. Mild liquid
dish detergent may be used to help break down dirt. Rinse thoroughly with clean water.
Note: Do not put in dishwasher or insert objects to clean the collector cell.
Tough residue such as tar from tobacco smoke may need additional applications or longer soaking.
6
Allow to dry completely outside of the air purifier. Do not use heated or compressed air to dry.
IMPORTANT: Do not reinsert the collector cell until it is completely dry. If the "Check Collector Cell" light
blinks red after replacing the collector cell, then the collector cell may still be wet. Remove the collector cell and
allow it to finish drying.
7
Place the collector cell back into the unit by sliding it straight down into the slots. The collector cell is
specially designed so that it can be inserted only in one direction.
Replace the top cover, sliding back to lock into place. Be sure the top cover and front grill are securely
8
closed or the unit will not operate.
9
Reset the "Check Collector Cell" timer by holding down the Air Revitalizer button until the "Check Collector Cell"
light blinks three times.
E
N
G
®
cleaner thoroughly between each cell plate and cover each surface. Allow the cleaner
L
I
S
H
2
3
1
9
9
Oreck
®
Assail-a-Cell
cleaner is an excellent
way to clean the
Collector Cell.

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido