3
INSTALLATION.
The following notes refer to the "Schematic diagrams" of
par. 4 and the "Installation Pictures" of par. 5.
For completeness of information must be consulted to-
gether with the Instructions Manuals supplied with the
power sources.
The operations of installation brought back of
continuation must be executed only by qualified
personnel.
All electrical connections must be carry out in full
compliance with current safety laws.
E
N
5
8
WARNING !
1
4
3.1
Art. 372 -374
a) Make sure the power source power cord is disconnected
from the power socket
b) remove the two plastic frames of the power source
c) remove the left side panel of the power source (power
source front view)
d) Fix the support 1 at the bottom panel of the power
source using the express 2 screw holes provided, as
indicated in Fig.;
e) Fix the power supply 2 to the support 1;
f) Fix the 10-pin circular connector of connection 4 in the
special hole in the rear panel of the power source (CN5
in Fig.).
g) Connect the connection 4 to the power supply 2, RED
wire to the + V terminal, BLUE wire to the –V terminal.
h) Connect one end of connection 3 to the power supply 2,
in terminals L-N and the other end to the transformer
(38), terminals 0 - 220 V. Close the power source
carpentry by performing steps b and c in reverse way.
Fig. 2
3
2
3301068