Troubleshooting - Kohler Purist K-1191-L Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct all electrical problems. For warranty service, contact your distributor.
Symptoms
1. Product does not
start.
2. Green Light in
On/Off" control
switch flashes
before bathing well
is full of water.
3. Water does not
cascade evenly over
entire bathing well
entire bathing well
rim.
4. Product stops
automatically before
y
18 minutes
18 minutes.
Noisy operation
y p
Water temperature
drops significantly
over 20 minute
operation.
operation
Chromatherapy
lights not working.
g
g
Kohler Co.
Probable Causes
A. No power to unit.
B. On/Off" control switch does not
light up or flash when unit is running
or fill as required.
C. Pump/motor does not work.
D. Control does not work.
A. Spout fills directly into overflow
channel.
B. On/Off" control switch does not
light of flash when unit is running or
filled as required.
C. Pump motor does not work.
D. Control does not work.
A. Unit is not level.
B. Bathing well ports are blocked.
A. GFCI trips.
B. Motor overheated and protection
device activated.
A. Pump/motor rattles.
B. Pump/motor rattles.
A. Heater manual reset limit switch
tripped. Indicator light should be on
during operation.
B. Heater does not work- indicator
light will not turn on.
A. Light fails to turn on.
B. Light fails to turn on.
Recommended Action
A. Turn on power to unit, or correct
source of power loss. Refer to
installer/dealer.
B. Check wiring or replace On/Off"
control switch. Refer to installer/dealer.
C. Rebuild or replace pump/motor. Refer
to installer/dealer.
D. Check wiring or replace control.
A. Adjust/reinstall spout to fill bathing
well. Refer to installer/dealer.
B. Check wiring or replace On/Off"
control switch. Refer to installer dealer.
C. Rebuild or replace pump/motor. Refer
to installer dealer.
D. Check wiring or replace control. Refer to
installer/dealer.
A. Add or remove shims until unit is
level.
B. Remove blockage.
A. Identify source of fault and correct.
Refer to installer/dealer.
B. Check for blockage of motor vent.
Allow motor to cool, then remove
blockage. Check for blockage and
A. Cut pump branding straps.
B. Check wiring or replace heater. Refer
to to installer/dealer.
A. Press the reset switch button.
B. Check wiring or replace heater. Refer
to installer/dealer.
A. Open switch control box and make
sure both wires are properly connected.
B. Replace lighting unit.
9
B
1012493-5-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Purist k-1191-lcPurist k-1191-rPurist k-1191-rc