Problem
Battery shear does not start.
(L1)
flashes green [ Fig. O2 ]
Battery shear does not start.
¥
Error-LED
flashes red [ Fig. O2 ]
Battery shear can no longer be stopped
¥
Error-LED
illuminates
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.
6. TECHNICAL DATA
Battery Shear
Unit
Strokes
1/min
Width of grass blade
mm
Length of shrub blade
cm
Weight
g
Sound pressure level L
1)
PA
dB (A)
Uncertainty k
PA
9853-20.960.01 A6 Short.indb 31
Possible Cause
Battery is empty.
Blade is blocked (overcurrent).
Start lever is stuck.
Battery error / battery defective.
Value
Value
Value
Value
(Art. 9853)
(Art. 9856)
(Art. 9857)
(Art. 9854)
with grass
with grass
with shrub
with shrub
blade
blade
blade
blade
1000
1000
1000
1000
80
–
80
–
–
12.5
–
12.5
575
640
635
700
< 70
< 70
< 70
< 70
3
3
3
3
Remedy
v Charge the battery.
v Remove the obstacle.
v See 1. SAFETY.
v Contact the GARDENA Service.
Battery Shear
Unit
Value
(Art. 9853)
Sound power level L
2)
WA
measured / guaranteed
dB (A)
Uncertainty k
WA
Hand/arm vibration a
1)
< 2.5
vhw
m/s
2
Uncertainty k
1.5
a
Measuring process complying with:
1)
Value
Value
Value
(Art. 9854)
(Art. 9856)
(Art. 9857)
with shrub
with shrub
blade
blade
79 / 80
79 / 80
0.35
0.4
< 2.5
< 2.5
< 2.5
1.5
1.5
1.5
EN 60745-2-15;
2)
RL 2000/14/EC
31
06.08.18 13:37