Programme Table - Grohe EUROSMART COSMOPOLITAN E 36 334 Manual Del Usuario

Ocultar thumbs Ver también para EUROSMART COSMOPOLITAN E 36 334:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13

Programme table

The infrared electronics provide seven preset programmes for selection.
Programme
1
Temporary shutoff*
2
Automatic flushing*
Flush interval
Flush duration
Usage-dependent
Usage-independent
Duration of thermal disinfection
1
*
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for
3 minutes even if an object is detected.
2
*
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is
initiated for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72
hours (usage-dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose/thermostat dirty
• Water supply restricted
Water temperature
• Temperature incorrectly set
too high or too low
• Dirty filters or defective non-return valve
(only with 36 336)
1
2
3
Active
Active
Active
Inactive
Active
Active
-
72 h
24 h
-
5 min
5 min
-
x
-
x
3.5 min
3.5 min
11 min
Remedy
- Open shut-off valves, isolating valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves,
isolating valves
- Adjust temperature
- Replace filters and non-return valve
4
5
6
Active
Active
Inactive
Active
Active
Inactive
72 h
72 h
-
10 min
1 min
-
x
x
-
-
3.5 min
3.5 min
3.5 min
7
Inactive
Active
72 h
5 min
x
3.5 min
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eurosmart cosmopolitan e 36 335

Tabla de contenido