INSTRUCTION MANUAL
EN
AIR PURIFIER PO200
GENERAL DESCRIPTION
1. Air exhaust
2. Control panel
3. Filter cap
4. Air intakes
5. Body
6. handle
SPECIFICATION
• power: 60 W
• voltage: 220-240V~ 50Hz
• noise level: 34-58 dB
• UV lamp
- wave length: 390 nm
- life: 10000 h
• area: 30 m
2
• CADR: 230 m
/h
3
INTENDED USE
PO200 air purifier definitely improves quality of air in the premises with its application of the 5-level
filtration system including the combination of: the 3-layer filter, ioniser and Uv lamp.
The appliance eliminates, among others:
• mechanical pollution (dirt, solid particles of smoke and combustion gases),
• mites growing in household dust,
• animal hair and skin (which are strong allergens for many persons), grass, tree and flower pollen,
• mould and fungi spores, bacteria and viruses.
PANEL STEROWANIA
A – signalling filter replacement
B – activation / deactivation of ionisation
C – activation / deactivation of the night mode
D – activation of the automatic mode
E – activation / deactivation of the Uv lamp
F – main switch
G – air quality check lamp
H – filter check lamp
I – air blowing control
J – activation / deactivation of the timer
10 EN
1
6
5
Fig. 1
A
B
C
J
2
3
4
Fig. 2
D
E
F
I
H
G