Replacing the fuse

If a short circuit occurs by overload of the fan(s),
the fuse will blow. If the Clima Control does not
operate in extreme cases, that could also indicate
that a fuse has blown.
Then, the fuse must be replaced.
The fuse is placed on the left side of the controller,
left of the outlet. Remove the fuse from the black
casing by using a screwdriver. Now, the fuse can
be replaced by a new one. A spare fuse is
supplied.
Put the new fuse in the black casing and place
them back in the holder. Rotate the screwdriver a
quarter turn to the right to close.
If the fuse of the fan has blown the
Clima Control itself and the possible connected
devices will remain operating.

TECHNICAL SPECIFICATIONS:

Power supply:
Consumption:
Maximum fan capacity:
Adjustment range TMP:
Adjustment range TMP hysteresis: 0.0 to 5.0 C.
Adjustment range TMP off set:
100 to 240 Volt
3 Watt (with sensor, without fan)
7 Amp / 1700W
14 Amp / 3400W
10.0 to 45.0 C.
-5.0 to + 5.0 C.
11