ASSEMBLING DUST INTAKE HOSES TO
BLOWER AND MOTOR ASSEMBLY
Keep dust caps installed at all times
over intake ports. Remove a dust cap only when a
flexible hose is attached to the intake port.
Always disconnect dust collector from
the power source before connecting or disconnecting
intake hose.
The dust collector is supplied with a 4" (101 mm) dia.
flexible dust intake hose.
1. To assemble the intake hose (A) Fig. 22, to the blower
assembly, pull the dust cap (B) from the dust intake
port (C) and slide the dust cap collar (D) farther onto
the dust intake port (C) as shown. IMPORTANT:
DO NOT REMOVE THE INTAKE CAP FROM THE
INTAKE PORT.
2. Place hose clamp (E) Fig. 22, on one end of flexible
hose (A) and assemble the hose to dust intake port
(C). Tighten hose clamp (E).
OPERATIONAL CONTROLS AND ADJUSTMENTS
For operator safety, do not operate the machine with any dust intake holes uncovered. The
rotating fan, located inside the blower housing, is accessible through the dust intake port and can be hazardous.
Always wear proper apparel. Do not wear jewelry. Keep your fingers and all foreign objects out of the dust intake
port. Follow the safety rules in this manual.
STARTING AND STOPPING THE DUST COLLECTOR
The "ON/OFF" switch is located on the side of the motor.
To turn the machine "ON", push the start button (A)
Fig. 23. To turn the machine "OFF", push stop button (B).
Make sure that the switch is in the
"OFF" position before plugging in the power cord.
In the event of a power failure, move the switch to
the "OFF" position. An accidental start-up can cause
injury.
LOCKING THE SWITCH IN THE "OFF"
POSITION
IMPORTANT: When the machine is not in use, the
switch should be locked in the "OFF" position to prevent
unauthorized use, using a padlock (C) Fig. 24 with a
3/16" (4.8 mm) diameter shackle.
Should you wish to operate your dust collector with a
second intake hose, contact CUSTOMER CARE CENTER
at 1-800-223-7278 to purchase the hose and install as in
STEPS 1 and 2 above.
Whenever one of the dust intake ports is not in use,
always be sure the dust cap is properly installed in the
intake port for operator safety.

OPERATION

Fig. 23
Fig. 24