Minimum operating pressure: 2 bar
Maximum operating pressure: 6,9 bar
Do not allow exposure to temperatures
below 4 °C
Maximum operating temperature: 30 °C
Nominal fl ow rates:
PURITY 450 Quell ST (100l/h)
PURITY 600 Quell ST (100l/h)
PURITY 1200 Quell ST (200l/h)
This system must be installed according to
local plumbing codes on the cold water line.
Replacement Cartridges
PURITY 450 Quell ST (No. 1004138)
PURITY 600 Quell ST (No. 1004136)
PURITY 1200 Quell ST (No. 1004133)
This system requires regular replacement of
the fi lter cartridge to maintain proper
operation. Varying scale, chlorine, sediment,
or organic substance levels may affect
replacement frequency.
The above listed Water Filter Systems have been tested and certifi ed under NSF/ANSI 42 for reduc-
tion of chlorine, taste and odour. The performance of this product has been verifi ed and substantia-
ted as the test data summarised below indicates. These substances may not be in your water.
Test Data
Substance
Guidelines
Chlorine
NSF/ANSI 42
Testing Conditions:
Flow Rate:
1,89 l/m pH: 7,28
Pressure:
414 kPa Temperature: 21 °C
Refer to your Instruction Guide for more specifi c product and warranty information and to avoid
contamination from improper handling and installation. Performance will vary based on local water
conditions. The substances reduced by this product are not necessarily in your water.
Buyer's Signature
This appliance meets the domestic water treatment appliance Standards AS/NZS 3497 and AS/NZS
4348 for the following water treatment process:
40
USE GUIDLINES
SUBSTANCE REDUCTION
Average
Maximum
Infl uent
Effl uent
Concentration
Concentration
2,1 mg/l
0,11 mg/l
Date
Seller's Signature
Be sure to change the fi lter cartridge at least
as indicated in the capacity table (refer to
your Instruction Guide) or annually which
ever occurs fi rst, or whenever you detect a
change in taste, odour, or a decrease in fl ow.
As an option the water fi lter system with
MDU (Measuring and Display Unit) can be
used, which assists in determining when the
cartridge must be changed.
Please ensure that a backfl ow prevention
device, meeting the requirements of AS/
NZS 3500.1, is installed on the water supply
inlet to the fi lter unit
Caution Do not use with water that is
microbiologically unsafe or of unknown qua-
lity without adequate disinfection before or
after the system.
Minimum
Percent
Removal
Concentration
94,7 %
Average
Average
Effl uent
Percent
Removal
0,06 mg/l
97,1 %