2. ELECTRICAL CONNECTIONS

OUTPUT CONNECTIONS FOR THE CONTROL UNIT 1 / MOTOR 1
• Connect the output COM 1 (clamp 7) to the input COM of the control unit 1
• Connect the output OPEN 1 (clamp 8) to the input OPEN or STEP-BY-STEP of the control unit 1
• Connect the output CLOSE 1 (clamp 9) to the input CLOSE or PEDESTRIAN of the control unit 1
• Connect the output STOP 1 (clamp 10) to the input STOP of the control unit 1
• Connect the output FOTO 1 (clamp 11) to the input FOTO of the control unit 1
• Connect the output EDGE 1 (clamp 12) to the input EDGE of the control unit 1
OUTPUT CONNECTIONS FOR THE CONTROL UNIT 2 / MOTOR 2
• Connect the output COM 2 (clamp 1) to the input COM of the control unit 2
• Connect the output OPEN 2 (clamp 2) to the input OPEN or STEP-BY-STEP of the control unit 2
• Connect the output CLOSE 2 (clamp 3) to the input CLOSE or PEDESTRIAN of the control unit 2
• Connect the output STOP 2 (clamp 4) to the input STOP of the control unit 2
• Connect the output FOTO 2 (clamp 5) to the input FOTO of the control unit 2
• Connect the output EDGE 2 (clamp 6) to the input EDGE of the control unit 2
INPUT INTERFACE CONNECTIONS B.RO4CM2CT
Connect the wired buttons to the interface considering the following:
• The input OPEN activates contemporarily the output OPEN 1 and OPEN 2
• The input CLOSE activates contemporarily the output CLOSE 1 and CLOSE 2
• The input OPEN 1 activates the output OPEN 1
• The input CLOSE 1 activates the output CLOSE 1
• The input STOP activates contemporarily the output STOP 1 and STOP 2
• The input PHOTO activates contemporarily the output FOTO 1 and FOTO 2
• The input EDGE activates contemporarily the output EDGE 1 and EDGE 2
• Connect the receiver antenna to the clamp 15 and the earth (braiding) of the antenna to the clamp 16
• Supply power to the interface between the clamp 13 and 14 with a tension of 230 Vac
ATTENTION! Remove the radio module of the control units to be interfaced and memorize the transmitters
directly on the interface. We recommend to set the working of the inputs of the control unit which are to
interface in the modality OPEN-CLOSE (in place of the modality step-by-step and pedestrian) if possible.
6-1621987 rev. 3
3 / 8