Descargar Imprimir esta página

Bticino MyHome 4073 Manual Del Usuario página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
Before performing any actions on the siren, make sure that the
system is in maintenance mode.
The flashing of the siren flash LED when exiting maintenance
mode indicates an inversion of the BUS polarity.
If the red BUS LED comes on, invert the polarity of the BUS.
Not compatible with sirens 4072A/4072L.
If a second siren is installed as part of the system, the installation
of another 4073 is also required.
LED and configuration switch:
Bring the central unit into "Maintenance" and disconnect batteries and SCS bus to modify the configuration.
System with
E46ADCN or
E49 power
In case of primary network power supply interruption, system autonomy is ensured by
supply
the battery installed inside the siren itself.
This solution means that only one battery can be used, instead of the two normally
used in traditional systems, therefore reducing maintenance and increase system
reliability by keeping safety levels unchanged.
Configure the siren as shown above.
System with
E47ADCN
power supply
It's presence is useful for notification purposes, but is however not compulsory, as the
system back-up battery will be connected to the power supply unit.
The internal housing of the siren houses the siren self-powering battery itself. A 2 Ah
battery will therefore suffice.
Configure this siren as shown above.
Foam
protection
The foam protection can be enabled using the SW2 configuration switch.
SW2 = ON (Foam protection enabled)
Type of power
supply
Foam sensors
Second siren
Foam
protection
enable
Main siren
1
2 3
SW1
SW2
1
2 3
SW1
SW2
LED notifications
LED
ON
Green power supply
Power supply active
LED
Red BUS LED
BUS polarity inverted
Battery polarity
Red battery LED
inverted
Power supply LED
BUS LED
4
If a higher degree of system autonomy is
desired, a second siren can be installed on
the system, configured as shown above.
4
If a second siren is desired, in order to have
two notification points, a second siren can
be installed on the same system, configured
as shown above.
1
2 3
4
SW1
SW2
4
OFF
Power supply disabled
BUS polarity correct
Battery polarity correct
Battery
Battery LED
connector
Removable clamp for BUS connection
Secondary siren
1
2 3
4
SW1
SW2
1
2 3
4
SW1
SW2

Publicidad