GreenWorks 4104907 Manual De Utilización página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
EN
DE ES IT FR PT NL RU FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET
OVERVIEW(SEE FIGURE 1.)
1 compressor
2 pressure vessel
3 condensate outlet
4 safety valve
5 connection for compressed air (quick
coupling), regulated com pressed air
6 manometer control pressure
7 pressure regulator
8 manometer boiler pressure
9 ON/OFF Switch
10 air filter / air filter housing
11 oil sealing plug
12 oil inspection glass
13 oil discharge plug
14 transport handle
COMMISSIONING
Assembly (depending on model)
1. Mount the tyres as shown (see fig. 2).
2. Mount the rubber feet as shown (see fig. 3)
3. Screw the enclosed air filter (10) onto the air inlet
(see fig. 4)
Check condensate outlet
Ensure that the condensate outlet (3) is closed.
Fill oil
1. Unscrew the oil plug (11) .
2. Fill oil until the centre of the oil inspection glass (12)
or the marking.
3. Screw back in (11) the oil plug.
Installation
The positioning site of the device has to meet the
following requirements:
– Dry, protected from frost
– Stable, horizontal and even surface
Wrong positioning might cause serious accidents.
– Secure the device against rolling away, tilting and
slipping.
– Safety installations and operating elements have
to be easily accessible at any time.
– Do not place the device on its side. Oil might
leak!
Transport
– Do not place the device on its side. Oil might leak!
– Do not pull the device from the hose or mains cable.
English (Original Instructions)
DANGER
Transport the device at the transport handle (14).
OPERATION
Power-supply connection
High voltage.
Operate the device in dry surroundings only.
Operate the device only at a power source meeting
the following requirements: Wall sockets installed
according to regulations, earthed and tested; fuse
protection according to the technical data.
Position power supply cable so it does not interfere
with the work and is not damaged.
Check every time if the device is switched off, prior to
plugging the mains plug into the socket outlet.
Protect power supply cable from heat, aggressive
liquids and sharp edges.
Use only extension cables with sufficient core cross-
section.
Use extension cables for outdoor areas. When working
outdoors, only use the correspondingly marked
extension cable approved for this purpose.
Do not switch off the compressor by pulling the mains
plug, but use the ON/OFF switch.
Always install an RCD with a maximum trip current of
30 mA upstream.
Generate compressed air
1. Switch on the device using the ON/OFF switch
(9) and wait, until the maximum boiler pressure
has been reached (compressor switches off). The
boiler pressure is shown at the boiler pressure
manometer (8).
Set the control pressure at the pressure regulator (7).
The current control pressure is shown at the control
pressure manometer (6) .
The set control pressure must not exceed the
maximum operating pressure of the connected
compressed air tools!
2. Connect the compressed air hose at the
compressed air inlet (5) .
3. Connect the compressed air tool. Now you can
work with the compressed air tool.
4. Switch off the tool if you don't want to continue
working immediately. Afterwards pull the mains
plug.
2
DANGER
CAUTION

Publicidad

Tabla de contenido
loading

Tabla de contenido