Allmatic BOOMY4 Manual Del Usuario página 68

Operatore irreversibile ambidestro per passi carrai
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

At this point press a button of the stored transmitter (does not activate any command).
The display shows the position in the memory for 2 seconds if it was stored; otherwise the not word is print in the display for 2
seconds if it was not stored.
After 2 seconds the display returns to the SEE screen and you can run the function with another transmitter.
To exit the function press the "MENU" button, otherwise after 15 seconds without transmissions the control panel exits the function
showing the word tout on display.
30. DELETING SINGLE TRANSMITTER TRC
By accessing the trc voice you can erase a single stored transmitter from memory. To perform the function access the item, then
confirm with the extended press of the "MENU" button.
Hold down until the display prints the value 0, release the button. Select the location in the transmitter's memory. Press and hold
the "MENU" button until the display prints CLr, release the button.
To exit the function, briefly press the "MENU" button. If ERR appears on display, there are problems with the memory (for example,
empty position or disconnected memory).
31. ERASE ALL RADIO MEMORY trF
By accessing the trf menu entry you can delete all the transmitters learned. To reset access the item, then confirm with the
extended press of the "MENU" button.
Hold down until the display prints the value 0, release the button. Press and hold the "MENU" button again, starts a countdown
"d80, d79, ... , d01" finished which reset is executed and don is displayed.
31. PARAMETER SId
Parameter not in use.
9.10 ADJUSTMENT OF BOOM MOVEMENT
For a correct adjustment of the movement of the boom take into account the operation of the following parameters:
SPnc = fully operational speed
SPLc = slow down speed
LSIc = amplitude of the slow down area
drac = time to switch from SPno to the slow down speed
WARNING! The parameters and the drawing refer to the closing
movement of the boom.
32 / 36 - English
SPnc
drac [sec]
SPLc
LSIc
6-1622396 - rev. 3 - 21/09/2021