getting started
Setting up the spa status transmitter
Connect the spa status transmitter to the appropriate cable
adapter that comes with the kit.
For MSPA-MP & M-Class spa systems:
• On MSPA-MP & M-Class spa systems, use Mini DIN to 4-pin
MTA-100 cable adapter (P/N 9920-401030).
P4 connector on PCB ( "I2C" or "COM")
to Mini-DIN Female
MTA-100 Male connector to device
Spa Status Transmitter
(spa watch, in.watch, TSC-24, djs, etc)
• Open the front cover of the MSPA-MP or M-Class spa system
to get access to the spa controller printed-circuit board (PCB).
Please refer to the spa user's manual for more details.
• Disconnect the device connected to the P4 connector on the
printed-circuit board labeled "I2C" or "COM" (e.g.: spa watch,
in.watch, TSC-24, djs, etc).
• Now, connect that device to the MTA-100 male connector
of the cable adapter.
8
MTA-100 Female connector to
• Finally, connect the MTA-100 female connector of the cable
adapter to the P4 connector on the spa controller printed-
circuit board (PCB).
MTA-100 Male
in.watch
Spa status
transmitter
MTA-100 Female