14) Check correct adjustment of the side spring latches. On pressing the bar all the way, the spring latch must be on its
own stop. If necessary, remove screw F, adjust the threaded rod until bringing the spring latch on its own stop and
retighten screw F.
15) Striker installation:
a) place the striker against the frame profile and bring it near the spring latch (fig. 7)
b) make sure the striker is in contact with the spring latch and that the door opens without interfering with the
striker when the bar is pressed. In case of interference or no contact, reposition the striker, using the shims
supplied in the pack, until finding the correct position (fig. 8)
c) make 2 Ø3,2 side holes using the striker as a template
d) secure the striker and possible shims with 2 Ø3,9 self-tapping screws supplied with the product
e) adjust the position of the striker to obtain correct compression of the door seals
f) make the Ø3,2 middle hole (using the striker as a template) and secure with the third Ø3,9 self-tapping screw
g) press the bar all the way and check correct opening of the door.
Fig. 7
Fig. 8
16) Fire barrier striker installation:
a) place the striker on the frame profile and bring it near the spring latch (fig. 9).
b) make sure the striker is in contact with the spring latch and that the door opens without interfering
with the striker when the bar is pressed. In case of interference or no contact, reposition the striker,
using the shims supplied in the pack, until finding the correct position (fig. 10, 11).
c) make 2 Ø4,2÷Ø4,5 side holes for the fixing screws.
d) secure the striker and possible shims with the 2 M4 screws supplied with the product.
e) press the bar all the way and check correct opening of the door.
Fig. 9
17) Rod cover
Cut the rod covers to the following dimensions on the side opposite that with the groove:
- length of top rod cover
- length of bottom rod cover
N.B.
If the emergency opener has been installed at the recommended height from the floor 1115 mm, the bottom rod cover will
not need shortening.
18) Fix the rod covers, the emergency opener covers and the spring latch covers.
ISTRUZIONI - INSTRUCTIONS - INSTRUCTIONS - INSTRUCCIONES
DOOR OPENING CURVE
Fig. 10
DOOR OPENING CURVE
Fig. 11
DOOR OPENING CURVE
X - 2
Y - 2
- 14/32 -
I0327001/03-2018