3. General Guidelines
• This device is a light effect for professional use on stages, in discos, theatres, etc. This
device should only be operated with an alternating current of max. 230Vac/50Hz and is
designed for indoor use only.
• This device is not designed for uninterrupted operation. Frequent operation breaks will
prolong the life of your VDL3002MR.
• Do not shake the device. Avoid brute force when installing or operating the device.
• Select a location where the device will be protected against extreme heat, moisture and dust.
Respect a min. distance of 50cm between the VDL3002MR's light output and the illuminated
surface
• Secure the device with an appropriate safety cable (VDLSC7 or VDLSC8).
• Do not use the device if the ambient temperature exceeds 45°C. The max. temperature for
the housing is 130°C
• Familiarise yourself with the functions of the device before actually using it. Do not permit
operation by unqualified people. Any damage that may occur will probably be due to
unprofessional use of the device.
• Use the original packaging if the device is to be transported.
• Note that all modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns,
electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void
the warranty.
4. Installation
a) Installing or Replacing a Lamp
CAUTION : Only install a lamp when the device is unplugged from the mains and replace it if it
has been damaged in any way.
• The lamps can reach temperatures of up to 700°C during operation, so you should let them
cool down for at least 10 minutes before replacing them
• Do not touch the halogen bulbs with your bare hands. Use a cloth to handle the lamps during
insertion and removal.
• Do not install lamps with a higher wattage as they generate higher temperatures than those
for which the device is designed.
• Use two JDC G6.35 lamps (120V/300W). Reference : LAMP300/120 or LAMP300/120OS.
1. Unscrew the cover on the side of the housing that holds the half ball with the coloured lenses.
2. Gently pivot the half ball.
3. Remove the old lamp and insert the new one.
4. Carefully reposition the half ball.
5. Fasten the cover.
Note : Do not operate the device with an open cover!!
VDL3002MR
Procedure
2
VELLEMAN