2.04 Connection of the control OPENING AND CLOSING with START
The connection of the opening control START (16-19) or closing (17-19)
can be done with any button or with a normally open contact.
In case of more devices, they should be serial connected.
If you use the terminal board START (16-19) it is possible
to connect a TIMER to program the opening of the gate.
It is possible to use a timer with automatic re-closing or
in step-by-step function (see TIMER WITH STEP-BY-STEP FUNCTION)
The contact of the TIMER should be normally open, and the contact should
be closed when the gate is opening. If the opening connection is available,
the terminal board no.16 should be parallel connected.
TIMER WITH STEP-BY-STEP FUNCTION ( DIP B 1 OFF - 2 ON)
If you connect a timer in the input START ( no.16-no.19), the gate closes when the timer contact is in OFF position (open
contact) but only in case the gate is open and the timer is connected for more than 10 seconds .
2.05 Connection of the opening limit switches and closing limit switches
In the picture the limit switches are shown,
but in this control unit you can use separately.
So you can use for example "Opening limit switch" or
"Closing limit switch".
The contacts of the limit switches are normally closed.
If the input of the FCA ( opening limit switches)
and FCC ( closing limit switches) are not used,
put the DIP 1 and 2 in ON and exclude FCA and FCC in the DIPA
2.06 Connection of the antenna
If you use only a small cable for the antenna,
for the frequency 433.92 Mhz, cut it at 17cm
and connect it to the terminal board no.21
2.07 Check of the connection
Check the exactly tension in the terminal boards, all NC red l.e.d. should be turned on.
When the control unit is powered , the lights L.E.D. which are in the inputs, are turned on when there is a closing common contact.
Normally the red led in the inputs STOP-FOTO-FCC –FCA are always turned on.
Normally the green led in the control START – PARTIAL OPENING are turned off.
Look LED L1TEST when correct programmed, should flashes constantly or with a single/double flashing.
Check the safeties, the gate should go in the right direction, it should open firstly.
.
21
20
19
18
17
nd closing limit switch
21
20
19
18
17
16
15
CLOSE
21
20
19
18
17
16
15
16
15
14
13
12
11
10
14
13
12
11
10
OPEN
14
13
12
11
10
7

Publicidad

Tabla de contenido
loading

Tabla de contenido