Blanking Of Motion Zone; Djust Sensitivity - CARLO GAVAZZI Guardian 1 Manual Del Usuario

Ocultar thumbs Ver también para Guardian 1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
MAN Guardian MUL_15-029-368_MAN Guardian MUL 25/08/10 15.01 Page 9
The motion zone can be blanked in 7 steps for all three directions using the 3
rotary switches "Left", "Center" or "Right" (see fig. 9).
Fig. 9
MOTION AREA ADJUSTMMENT
MIN
MAX
MIN
LEFT
Blanking left
fter adjusting the zones it must be verified that the motion zone is active in
the wanted area by a "walking test".
Immunity
Max Immunity
1
Min
The sensitivity rotary switch allows settings in 7 steps. In order to select the
right compromize between sensitivity and immunity.
normal setting would be 3-5 (Normal light condition) (4 is default).
• For indoor applications with light shadows, setting at 6-7 can be used.
• In outdoor conditions with strong light, rain or snow, a setting from 1-2
could be selected (strong light with heavy shadows).

Blanking of Motion Zone

MAX
MIN
MAX
CENTER
RIGHT

djust Sensitivity

MIN
SENSITIVITY
2
3
Recommended settings
Blanking center
Blanking right
3
MAX
4
5
6
Presence zone
Motion zone
Sensitivity
Max Sensitivity
7
Max
9

Publicidad

Tabla de contenido
loading

Tabla de contenido