Models
Style
Lever,
5LK2A41
90° Angle
Lever,
5LK2A41-EU
90° Angle
Lever,
5LL2A41
90° Angle
Lever,
5LN2A43
90° Angle
Lever,
5LN2A43-EU
90° Angle
* K = Vibration measurement uncertainty
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-off, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 16575649 and table on page 2. Maintenance frequency is shown in a
circular arrow and defined as h=hours, d=days, and m=months of actual use. Items identified as:
1. Air filter
2. Regulator
3. Lubricator
4. Emergency shut-off valve
5. Hose diameter
6. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
Free
Stall
Speed
Torque
rpm
in-lb (Nm) ft-lbs (Nm) Pressure
2000
45 (5.1)
2000
45 (5.1)
1500
60 (6.8)
700
120 (13.6)
700
120 (13.6)
7.
Coupling
8.
Safety Air Fuse
9.
Oil
10. Grease - through fitting
11. Grease - through fitting
12. Grease - through fitting
Chuck
Sound Level dB(A)
Capacity
(ANSI S5.1-1971)
(ISO3744)
1/4 (6)
---
1/4 (6)
79.1
1/4 (6)
---
1/4 (6)
---
1/4 (6)
78.9
Vibration (m/s²)
(ISO28927)
Power
Level
*K
---
< 2.5
---
---
< 2.5
---
---
< 2.5
---
---
4.0
0.8
---
4.0
0.8
16572182_ed2