LED STATUS INIDICATOR TABLE
NORMAL INDICATION
6V/12V mode selected
In soft start phase
In charging phase
In Float mode or Maintenance
ABNORMAL INDICATION
Output reverse polarity or shorted
Charging timer timed out
Battery slight sulphated
Battery heavily sulphated or cells shorted
6V / 12V mode incorrect selection
TROUBLE SHOOTING
Types of Problems
Indication
Charger does not
No Indicator
work?
lights on.
Charger has no DC
Fault LED is
output?
On.
Long charging time,
Fault LED is
Full light does not
ON.
come on?
Long charging time,
Fault LED is
Full light does not
Flash.
come on?
MAINTENANCE
The battery charger is maintenance free. If the power cord is damaged, the charger must be left to the reseller for maintenance. The
case should be cleaned occasionally. The battery charger should be disconnected from the power while cleaning.
| www.bs-battery.com
Possible Causes
- No AC power.
- Output is short circuited
- Reverse polarity connec-
tion to Battery.
- Battery capacity too
large
- Battery is defective.
- Battery cells internal
shorted, battery heavily
sulphated.
WHITE LED ON
BLUE
Charging light FLASH
BLUE
Charging light ON
GREEN
LED ON
RED
Fault LED ON
RED
Fault LED ON
GREEN
Fault LED FLASH
RED
Fault LED FLASH
REDFault LED FAST FLASH
Suggested Solution
- Check AC connections and make sure Power Point is swit-
ched ON.
- Check DC connection between charger and battery and
make sure they are not short circuiting.
- Check that the crocodile clips haven't fallen off the battery.
- Check that the crocodile clips / ring terminals are connec-
ted to the correct polarity.
- Check the charger specification matches the battery
capacity.
- Battery cannot be charged and must be replaced.