Important:
1. The accuracy of a weather forecast, when only using
pressure trends, is approximately 70 to 75 percent.
2. The weather forecast symbols may not reflect current
weather condition. The symbols are forecasting the
future.
3. A 'SUNNY' forecast covering the nighttime reflects fine
clear weather.
HOW TO RESET THE UNIT
Press RESET to return all settings to the factory values, which
are 1-1 (1st of January) for date, 00:00 for time and 0:00 for the
alarm that is deactivated.
The button is required only when the unit is not operating in a
favorable way, such as in the rare case of a malfunction.
HOW TO WALL MOUNT OR
USE TABLE STAND
MAIN UNIT
Flip open the table stand to place the unit on a steady, flat
surface. Or you can use the recessed holes on the back to mount
it on a wall.
Wall-mount
REMOTE THERMO SENSOR
The unit can be wall-mounted using its recessed screw hole or
place on a flat surface using the removable stand.
Wall-mount
MAINTENANCE
When handled properly, this unit is engineered to give you years
of satisfactory service.
Table Stand
Table Stand
Here are several product-care suggestions:
1. Do not immerse the unit in water. If the unit comes in contact
with a liquid, dry it immediately with a soft lint-free cloth.
2. Do not clean the unit with abrasive or corrosive materials.
Abrasive cleaning agents may scratch the plastic parts and
corrode the electronic circuit.
3. Do not subject the unit to excessive force, shock, dust,
temperature, or humidity. Such treatment may result in
malfunction, a shorter electronic life span, damaged batteries,
or distorted parts.
4. Do not tamper with the unit's internal components. Doing so
will terminate the unit's warranty and may cause damage.
The unit contains no user-serviceable parts.
5. Only use new batteries as specified in this instruction manual.
Do not mix new and old batteries as the old batteries may
leak.
6. Read this instruction manual thoroughly before operating the
unit.
SPECIFICATIONS
MAIN UNIT
Clock Functions
Radio Control
Calendar
Clock Time
Alarm Duration
Snooze
Accuracy
General specification
Battery Type
LCD Dimension
Unit Dimension
Unit Weight
Temperature Measurement
Operating Temperature
Temperature Resolution : 0.1°C to (0.2°F)
6
: Auto synchronizes current time
and date by Radio signal
generated from Germany DCF77
: Day of week in English / German /
French / Italian,
Current date / month format
: 24-hour format
: 2-minute crescendo
: 8 minutes
: +/- 0.5 second/day
: 4 piece of UM4 or "AAA" size
1.5V battery
: viewing area - 155 x 107 mm
: 298 x 177 x 24 mm (H x W x T)
: Approx. 660 g
(not including batteries)
: -5°C to 50°C (23.0°F to 122°F)