Appendix; Message Codes - Stanley FatMax Tru Laser Measurement TLM300 Manual De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
D
It is possible to use the "Minimum/maximum
GB
measuring" by pressing the ON/MEASURING -
key {A, 1} longer. The minimum measuring is used
F
for the first two measurements, the maximum
measuring for the third measurement.
I
Press the TRAPEZOID - key {A, 6} for the trapezoid
function. The trapezoid symbol appears on the
E
display. The length to be measured appears flashing
on the display. Take the necessary measurements.
P
The result and the single measurements appear on
NL
the display.
Press the TRAPEZOID - key {A, 6} after the measure-
DK
ment long to display additional trapezoid information
such as e.g. roof length, roof angle and area.
S
Storage of Constants/Historical
N
storage
FIN
Storage of a Constant
J
It is possible to store and recall a frequently used
value e.g. height of a room. Measure the desired
CN
distance, press MEM - key {A, 14} long until the
device beeps to confirm the storage.
ROK
Recalling the constant
PL
Press RCL - key {A, 14} short to recall the constant.
Press EQUAL - key {A, 8} to take result from the
HR
memory for further calculations.
H
Historical storage
Press HISTORY - key {A, 15} short and the previous
RUS
20 results (measurements or calculated results) are
CZ

Appendix

GR
shown in reverse order. Using the PLUS - key {A, 7}
and the MINUS - key {A, 12} allows to navigate in the
historical storage. Press EQUAL - key {A, 8} to take
a result from the stack to use for further calculations.
Timer
Press and hold TIMER - key {A,15} to start the timer
function. With the PLUS - key {A,7} and the MINUS -
key {A,12} the delay time (5 - 60 seconds) can be
adjusted. The remaining seconds until measurement
are displayed. Press the ON/MEASURING - key {A,1}
to start the countdown. The last 5 seconds are
counted down with a beep. After the last beep the
measurement is taken.
Appendix

Message Codes

All message codes will be displayed with either "InFo"
or "Error".
The following mistakes can be corrected:
InFo
Cause
204
Calculation error
206
No endpiece detec-
tion
252
Temperature too high Cool down instrument
253
Temperature too low Warm up instrument
8
Remedy
Repeat procedure
Attach endpiece prop-
erly. If error still occurs,
replace endpiece with
a new one (replace-
ment part).
Stanley TLM 300 1.0.0 gb

Publicidad

Tabla de contenido
loading

Tabla de contenido