7. assemble the device in reverse order, all gaskets must be properly
placed in their groove and greased with Vaseline, and the fluorescent
lamp must be inserted all the way into the fitting until refusal.
FLUORESCENT LAMP REPLACEMENT
When the UV-C fluorescent lamp does not work – the diode (A) goes off
– it should be replaced as follows:
1. disconnect the device by pulling the plug from the power supply
socket,
2. disconnect the device from the water circulation, remove any remain-
ing water inside and wipe dry,
3. turn the fitting grip (10) clockwise, according to the „OUT" arrow
(fig. ),
4. remove the fitting,
5. remove the fluorescent lamp from the fitting and press a new one in
until locked,
NOTE Do not touch the glass of the fluorescent lamp; remove possible
marks with a dry cloth.
6. place the fitting (10) along with the mounted fluorescent lamp (8) in
the housing (otherwise the fluorescent lamp will not work).
The manufacturer grants warranty for a period of 24 months, counting
from the date of purchase. The warranty covers damages arising from a
fault of the producer, i.e. defective materials or workmanship. It does not
cover the UV-C fluorescent lamp and mechanical and other damages
arising from improper handling of the device, or alterations made by the
buyer. For the purpose of repair it is necessary to send the device along
with the warranty card filled out by the seller to the address of the manu-
facturer or distributor. The date of manufacture entered in the warranty
card should fall in the scope of the date imprinted on the plug stabilizer.
The manufacturer shall in no way be liable on account of improper han-
dling of the device.