Replacing The Safety Filter Bag; Technical Data - Kärcher NT 801 B1 Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
English
Replacing the safety filter
bag

3. Technical data

When replacing the filter it is important that the corresponding
safety measures are adhered to; e.g. the filter should be replaced
in the open and not inside an enclosed space, and a respiratory
protection mask should be worn if necessary.
• Release the container by pulling the retaining clips upwards.
• Lift off the blower assembly, and lay it on its back.
• Before disposing of the full filter bag screw the cap into the
connection sleeve, and seal the outer foil with tape.
Installation:
• Push the filter bag sleeve onto the elbow section in the container,
and pull the outer foil over the edge of the container.
• Remount blower assembly onto the container, and lock the
retaining clips in place.
Important: Ensure that the blower assembly is seated properly
(location); switch position - towards the rear.
Container capacity ........................................................................80 L
Weight ..................................................................................... 27.0 kg
Blower specifications ............................................. 230/1~ 50,60 V/Hz
Power consumption ................................................................ 1200 W
Vacuum ............................................................................... 220 mbar
Air flow .................................................................................. 57 L/sec
Length x width x height....................................... 640 x 510 x 935 mm
Cable length .............................................................................. 7.5 m
Class of protection ............................................................................ I
Interference suppression level .......................................................... N
Sound level (according to DIN 45635 Part 1) ...................... 74 dB (A)
Mains cable: order no. .........................................................6.647-410
type ............................................................................ H07RN-F3G1.5
* BIA Test Certificate No. 8801853/1110
Staubtechnisch geprüft nach ZH 1/487 und Hinweise SBM 1/85.
Average level of permeability < 0.1%; Verwendungskategorie C
measured with Test Aerosol 3 (Quarz dust) in accordance with
a) ZH 1/487, para 2;
b) DIN 24184;
c) DIN 53887;
d) BIA Notes on Dust Filter Equipment 1/85
NT 801 B1
13

Publicidad

Tabla de contenido
loading

Tabla de contenido