Descargar Imprimir esta página

Aqua Medic M-Ventil Eco Manual De Instrucciones página 4

Ocultar thumbs Ver también para M-Ventil Eco:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 9
5.
Mount the other end of the flexible tube onto the pressure outlet of the pressure reducer and
tighten it.
6.
Now, a tube is mounted in the same way on the outlet (5). Here, you do not need to use a
pressure tube, you may use ordinary PVC-tube (6/4 mm, ¼").
7.
The free end is connected to the bubble counter inlet or to the CO
8.
If you use a pressure regulator with adjustable operating pressure, set it to 1 bar.
Note:
Always
solenoid
valve.
into
the
regulator
to use the original Aqua Medic bubble counter with integrated non-return valve.
3. Operation with timer
The CO
–consumption during the day (light phase) is determined primarily by the plants. In the
2
night (dark phase), the plants excrete CO
night time, it may even be harmful. The solenoid valve can be linked to a timer to meet these
specific requirements. An elegant solution is to connect the solenoid valve to the timer that
controls the light. The valve is then switched on and off together with the light.
4. Operation with pH controller
This operation mode should be preferred in comparison to others. It is the most exact and
economic version. Only the exact quantity required is fed into the system. It balances the loss that
is, for example, caused by water movements and aeration. Fluctuations of the pH-values are
avoided by an electronic control. This is an advantage for the creation of a well-balanced
environment.
The solenoid valve is not suitable for water. The maximum pressure must not exceed 1 bar.
5. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid.
Proof of Purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase. This warranty may not apply if any model
or production number has been altered, deleted or removed, unauthorised persons or organisations
have executed repairs, modifications or alterations, or damage is caused by accident, misuse or
neglect. Please note that the product is not defective under the terms of this warranty where the
product, or any of its component parts, was not originally designed and / or manufactured for the
market in which it is used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
Current manuals are available for download at www.aqua-medic.de.
4
use
a
non-return
It
prevents
water
and
the
CO
–bottle
2
- Technical changes reserved – 02/2018
valve
between
from
flowing
and
may
cause
1. Body of the valve
2. Magnetic reel
3. Power cord
4. CO
5. CO
–gas. So it is not necessary to provide CO
2
–inlet.
2
the
aquarium
back
from
the
damage.
We
-inlet
2
-outlet
2
2
and
aquarium
recommend
during the

Publicidad

loading