The pressure reduction is
achieved by rotating the
adjusting screw to the working
pressure requested.
• Fulfils the requirements
of Directive 97/23/EC
concerning pressure
equipment.
• Materials fulfil the
requirements of FDA Title
21§1772600, BGA.
• Regulator available in
Primary or Secondary and
serial version.
• Safety Relief Valve prevents
increase of pressure in the
system.
• Inlet filter (gas in) for
protection of regulator and
system from foreign material.
• Range of working pressure:
Standard 0 - 3 bar.
Standard 0 - 4 bar.
Standard 0 - 7 bar.
• Venting Function.
• Max./min. ambient
temperature +45°C/+5°C
(working temperature min.
-40°C).
• Capacity: Max. 100 l/min.
• Max. inlet pressure 230 bar.
Auxiliary equipment
All pressure regulators are also
available for other pressure
applications and other pressure
values.
Regulator is available with shut
off valves, tail pipes and John
Guest connections.
Also available with one or two
relief valves, wall bracket and
tamper evident ring.
Cleaning and
maintenance
Always keep your equipment
clean to ensure optimum
function and safe use.
When performing cleaning
or maintenance jobs of the
regulator make sure that it is
disconnected and make sure
no media are entering the
component.
• Clean exterior with wet cloth.
• Please replace the gaskets
when necessary.
• In case of malfunction
(damage, trouble etc),
please contact your supplier.
5